XStream"燨EM燫F燤odule?燩roduct燤anual爒5.x00燵2006.02.24]?/DIV>
CN (Exit AT Command Mode) Command
AT Command: ATCN
Binary Command: 0x09 (9 decimal)
<Command Mode Options> CN Command is used
to explicitly exit AT Command Mode.
 
CO (DO3 Timeout) Command
AT Command: ATCO
Binary Command: 0x2F (47 decimal)
Parameter Range:   0  0xFFFF [x 1 second]
Default Parameter Value: 3
Number of bytes returned: 2
Related Commands: CD (DO3 Configuration),
DR (DI3 Configuration)
Minimum Firmware Version Required: 4.30
<Serial Interfacing> DO3 (Data Output 3) output
will return to default after no DI3 (Data Input 3)
status information is received during the timeout
period.
Use with CD = 1 or 2, DR = 1.
 
 
 
CS (DO2 Configuration) Command
AT Command: ATCS
Binary Command: 0x1F (31 decimal)
Parameter Range:   0  4
 
Parameter
Configuration
 
0
RS-232
 flow control
 
1
RS-485 TX enable low
 
2
high
 
3
RS-485 TX enable high
 
4
low
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: RT (DI2 Configuration),
TO (DO2 Timeout)
Minimum Firmware Version Required: 4.27D
<Serial Interfacing> CS Command is used to
select the behavior of the DO2 (Data Output 2)
pin signal. This output can provide RS-232 flow
control, control the TX enable signal (for RS-485
or RS-422 operations), or set the default level for
the I/O line passing function.
By default, DO2 provides RS-232
 (Clear-to-
Send) flow control.
 
 
 
 
 
 
CT (Command Mode Timeout) Command
AT Command: ATCT
Binary Command: 0x06 (6 decimal)
<Command Mode Options> CT Command is used
to set the amount of time of inactivity before AT
Command Mode automatically terminates. After a
CT time of inactivity, the module exits AT
Command Mode and returns to Idle Mode. AT
Command Mode can also be exited manually
using the CN (Exit AT Command Mode)
Command.
Parameter Range:   2  0xFFFF
 
[x 100 milliseconds]
Default Parameter Value: 0xC8 (200 decimal,
20 seconds)
Number of bytes returned: 2
DC (Disconnect) Command
AT Command: ATDC
Binary Command: 0x37 (55 decimal)
Related Commands: CB (Connection Duration
Timeout), CE (Connection Inactivity Timeout),
MD (RF Mode)
Minimum Firmware Version Required: 4.30
<Networking & Security> DC Command is used
(when in Multi-Streaming Mode (MD = 1 or 2))
to explicitly force the disconnection of an active
exclusive connection. If MD = 1, the base
module will force the disconnection of an
exclusive connection. If MD = 2, the remote
module will send a Disconnect Request Packet
to the base module.
牋牘?006燤axStream,營nc.燙onfidential燼nd燩roprietary?/DIV>
23?/DIV>
相关PDF资料
XIB-R BOARD INTERFACE RS232/485
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
02110102-000 SNSR TILT RATIO 60DEG 500MA FLNG
1-5209285-2 FOPC BOA 12DB FC/UPC BP SM
2-1693560-0 BOA 20DB LC/UPC BB
517SS16 MAGNETIC SENSORS BIPOLAR ICS
相关代理商/技术参数
XIB-R 功能描述:界面模块 RS-232/485 interface 24XStream 9XCite RoHS:否 制造商:4D Systems 产品:Serial Converters 通道/端口数量: 数据速率: 接口类型:USB, UART 工作电源电压:3.3 V, 5 V 最大工作温度:
XIB-U 功能描述:界面模块 USB interface board 24XStream 9XCite RoHS:否 制造商:4D Systems 产品:Serial Converters 通道/端口数量: 数据速率: 接口类型:USB, UART 工作电源电压:3.3 V, 5 V 最大工作温度:
XIC25040 制造商:XIC 功能描述:25040 24HR '6
XILINXPWR-079 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-080 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-081 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-082 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-083 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V